The Reasons For The Malfunction Of The Electric Steam Generator

The internal pressure of the electric steam generator system is constant. Once the pressure of the electric heating steam generator system suddenly drops and the instrument indication is abnormal, what are the causes of various faults in the electric heating steam generator? How to repair it? Let's take a brief look below.

1. The local radiator of the electric steam generator is not hot

One of these common faults will be the cause of gate valve failure. The drop of the gate valve disc inside the electric heater gas steam boiler will hinder the safe passage of heat flow. The solution is to open the cover of the gate valve for maintenance, or remove and replace the unusable gate valve. The second type will generate excessive gas in the steam collection tank and block the pipeline. The solution is to open the vent comments set in the system software, such as the manual watering door on the heat pipe radiator and the automatic vent valve on the steam collection box. The key to finding blocked pipes is to touch and add water.
The method of touching the electric steam generator with your hands is where the temperature is low, which is the problem. The method of adding water is to add water section by section, and then place the water in the middle of different pipes. If the water at one end continues to flow forward, then there is no problem at this end. If it flows for a while and then folds up, it indicates that the end has been blocked. Dismantle this part of the pipeline to eliminate blockages.

2. Sudden power or water outage when using an electric steam generator

When the gas boiler of the electric water heater loses water or loses power, if it cannot be solved, it will cause harm to the software of the electric steam generator system. If the electric heating gas steam boiler suddenly loses water during the entire application process, the appropriate method is to immediately turn off the switch power of the electric heating gas steam boiler.

In addition, place the accumulated water in the water storage tank into the electric steam generator boiler to prevent air combustion of the electric heater from damaging the heating furnace system software. If the power supply of the electric water heater gas boiler suddenly shuts off during the entire application process, the appropriate method is to close the discharge valve of the electric water heater gas boiler to ensure the internal working pressure of the gas boiler system software.